2009 Max Halvorson: Difference between revisions

From Psych 221 Image Systems Engineering
Jump to navigation Jump to search
imported>Psych 204
imported>Psych 204
Line 14: Line 14:


==Vessel Distortions==
==Vessel Distortions==
Spin-echo imaging can be used to refocus the loss of phase coherence and eliminate the large-vessel signal. For smaller vessels, the gradient changes rapidly over space relative…Loss of phase coherence �cannot be recovered �by spin-echo imaging (from Huettel et al. �text).
Spin-echo imaging can be used to refocus the loss of phase coherence and eliminate the large-vessel signal. For smaller vessels, the gradient changes rapidly over space relative…Loss of phase coherence cannot be recovered by spin-echo imaging (from Huettel et al. text).
 


==Purpose==
==Purpose==

Revision as of 07:59, 8 December 2009

Back to Psych 204 Projects 2009

Differences Between Spin-Echo and Gradient-Echo Imaging

Spin-Echo and Gradient-Echo imaging are two different methods of obtaining fMRI data that vary along various dimensions: the pulse sequence used to generate and obtain the signal, signal-to-noise ratio, and sensitivity to large blood vessels, to name a few.


Background

Gradient Echo

Gradient Echo images are generated by an applied gradient followed by an RF pulse sequence to excite slices one by one and collect data from each. Gradient Echo images have a stronger overall signal than Spin Echo images and the overall signal-to-noise ratio is higher. However, Gradient Echo images are prone to large distortions from large blood vessels, sinuses, and other inhomogeneities.

Spin Echo

Spin Echo images are generated by a 180-degree pulse following the applied gradient. This pulse realigns the dephasing spins and gives another shot at capturing data. Spin Echo images are weaker in signal and signal-to-noise ratio than Gradient Echo images. However, Spin Echo images should be less sensitive to distortions from large blood vessels and sinuses.

Vessel Distortions

Spin-echo imaging can be used to refocus the loss of phase coherence and eliminate the large-vessel signal. For smaller vessels, the gradient changes rapidly over space relative…Loss of phase coherence cannot be recovered by spin-echo imaging (from Huettel et al. text).

Purpose

Although Gradient Echo images have a stronger overall signal and signal-to-noise ratio and generally show more in most brain regions, Spin Echo images are theorized to avoid distortions due to large blood vessels and inhomogeneities. The hope of this study was to find areas in which Spin Echo images could reveal things in visual cortex that gradient echo could not. For example, areas like hV4...

Methods

MR Analysis

The MR data was analyzed using mrVista software tools.

Pre-processing

All data were slice-time corrected, motion corrected, and repeated scans were averaged together to create a single average scan for each subject. Et cetera.


Results

Conclusions

References - Resources and related work

Software: mrVista

Appendix I - Code and Data

Code

zip file with code

Data

zip file with my data